Send Message
Henan Weiguo Intelligent Technology Co., Ltd. 86-371-67169566 sales@wellgosensor.com
Reusable Wireless Fire Hydrant Button Fire Gas Detection System

Reusable Wireless Fire Hydrant Button Fire Gas Detection System

  • High Light

    Reusable Wireless Fire Hydrant Button

    ,

    GB 16806 Fire Hydrant Button

    ,

    Airradio Fire Hydrant Button

  • Type
    Sounder Vad
  • Action Current
    50mA
  • Specification
    101mm*137mm*43mm
  • Material Of Enclosure
    ABS
  • OEM/ODM
    Supported
  • E-Mail
    Sales@wgsensor.com
  • WhatsApp
    +8613333637163
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    WG Sensor™
  • Certification
    CEM
  • Model Number
    TCXH5415W
  • Minimum Order Quantity
    1pcs
  • Price
    1pc-39pcs/26USD ~ 40pc-999pcs/21USD
  • Packaging Details
    Carton,single device
  • Payment Terms
    L/C, T/T, Western Union, MoneyGram
  • Supply Ability
    10000000 pcs per year

Reusable Wireless Fire Hydrant Button Fire Gas Detection System

Wireless fire hydrant button for safety

 

Product Introduction:

 

The TCXH5415W wireless fire hydrant button (hereinafter referred to as the fire hydrant button) is suitable for installation in public places. When the fire pump is manually confirmed to start, press the start button on the fire hydrant button, the fire hydrant button is always on, and it can be sent to the controller through wireless communication technology Start the signal and start the fire pump at the same time; after the fire pump has been started, the fire hydrant button answer light is always on, the fire hydrant button sends an answer signal to the controller through wireless communication technology, and the fire hydrant button enters the state of waiting for the controller to reset. The controller can display the coded information of the fire hydrant button and make a sound.

 

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 0

 

Parameters:

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 1

 

 

Main Characteristics:

 

1. Battery model: CR17450 (with wire)

2. Rated working voltage: 3.0V

3. Working current: monitoring current ≤15uA

   Starting current≤10mA

4. Indicator light: Start light: red, always on when starting

    Fault light: yellow, flashes twice every 48s when the battery is under power, and periodically flashes when the communication fails after        being connected to the network

    Working light: green, flashing periodically when the communication is normal after entering the network

    Answer light: green, always on after receiving the answer signal

5. Coding method: automatically assigned by the controller during networking

6. Communication method: 470MHz FSK coded two-way communication

7. Communication distance: ≤50m

8. Transmitting power: <20dBm

9. Start mode: manually press the button

10. Reset method: special key reset

11.Starting parts form: reusable type

12. Use environment:

     Type: Indoor Atmospheric pressure: 86kPa~106kPa

     Temperature: -10℃~+55℃ Relative humidity ≤95%, non-condensing

13. Dimensions: 96mm×95mm×50mm

14. Shell material and color: ABS, red

15. Weight: about 190g (including battery)

16. Executive standard: GB 16806-2006 "Fire Fighting Linkage Control System"

     XF 1151-2014 "General Requirements for Wireless Communication Functions of Fire Alarm Systems"

Features:

 

1 Using a push-type structure design, the fire hydrant button needs to be reset with a special tool after it is pressed;

2. Adopting 470MHz wireless communication technology, without pre-buried wiring, convenient and quick engineering installation;

3.With battery low voltage detection function, it can reflect the battery power situation in time;

4.The use of microprocessor to realize signal processing and digital signal to communicate with the controller, the work is stable and reliable, and has a good ability to suppress electromagnetic interference.

 

Fault and Abnormal information processing and Regular Check:

 

Failure phenomenon reason Solution
The control panel has no status prompt after the device alarms The device is not connected to the network Restart the network operation
Device networking is unsuccessful Too far away from the control panel or interference sources nearby Move the device near the control panel, reconnect to the network and remove the source of interference
The device's red light is off Low battery or no battery inserted Replacement battery

Others:

 

Please refer to the product manual for details

 

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 2Reusable Wireless Fire Hydrant Button Fire Gas Detection System 3

 

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 4Reusable Wireless Fire Hydrant Button Fire Gas Detection System 5


Company Profile:

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 6

Henan Weiguo Intelligent Technology Co., LTD., founded in 2015, is an important subsidiary of Hanwei Electronics Group Corporation (Stock no.:300007) in the field of intelligent healthy, safe home and IoT business. Henan Weiguo Intelligent Technology Co., LTD., relying on the core sensor technology, focuses on gas and smoke alarm, air quality monitor, alcohol tester and firefighting products. Based on introduction of featured technology from both Hanwei Electronics Group Corporation and abroad, Henan Weiguo intelligent Technology Co., LTD., has developed into an innovative company with the collection of design, R&D development, production, sales and service. We will always be committed to becoming the leader in intelligent hardware, providing safe, healthy, environmentally friendly and intelligent working and living environment for families and users all over the world.

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 7Reusable Wireless Fire Hydrant Button Fire Gas Detection System 8Reusable Wireless Fire Hydrant Button Fire Gas Detection System 9

 

 

Reusable Wireless Fire Hydrant Button Fire Gas Detection System 10Reusable Wireless Fire Hydrant Button Fire Gas Detection System 11

FAQ
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the device according to your request.